Nazeeh Abdul-Hadi

VibeScope

Measure small motion from original video frames, then change the display gain without changing the displacement history or frequency estimate.

Display gain, fixed measurement

Original recorded synthetic frame72.
Original
The same recorded frame with visualization gain20.
Visualization ×20

Both stored gain runs analyze the original frames: 7.30 Hz and 0.280 px remain fixed. This control reveals recorded images, not a new measurement.

Actual original and gain-20 enhanced frames, followed by the identical gain-5 and gain-20 displacement traces and a spectrum from the original frames.
Recorded synthetic paired runs. Frame 72 shows original input and gain-20 visualization; all 240 displacement samples per gain and 120 positive-frequency bins are retained in the figure and source artifacts. Open full capture
Actual VibeScope workspace after reopening the saved gain-20 measurement following a server restart.
The recorded workspace reopened the saved gain-20 run after server restart. The source video, completed result and warnings remain part of the measurement history. Open full capture

Scope of this case

This is controlled synthetic image-plane evidence. Physical calibration, arbitrary-media and diagnostic accuracy are not established. Timing was explicitly unverified because ffprobe was unavailable; magnification is a visualization, not a new sensor measurement.

The problem

A convincing magnified video is not a displacement measurement. Display enhancement must remain separate from the original-frame signal used for quantitative analysis.

The mechanism

VibeScope tracks a selected image region against an independent stationary reference, derives displacement and frequency information from original decoded frames, and renders motion visualization separately. Exported reports, CSV and saved-run history retain the settings and measurement records.

The observed result

The recorded gain-5 and gain-20 runs have identical complete 240-sample signals, quantitative metrics and raw displacement CSV bytes, while their visualization settings and enhanced output differ. For the controlled 7.3 Hz / 0.28 px input, the observed result was 7.299959660082684 Hz / 0.2798920570385787 px. The saved gain-20 run reopened after server restart.

Foundations

Core inference runs in NumPy. The project separately credits its classical and learned research foundations; the optional EulerMormer runner invokes an external model and is not bundled into the core estimator.

Inspect the details

The original and enhanced frame pixels are retained at native 320 × 192 resolution; nearest-neighbor enlargement changes display size only. No selective contrast, color or denoising adjustment was applied for the portfolio figure.

The figure reads the browser-exported reports and CSVs. It performs no new estimator, fit, filter or physical experiment.

Recorded evidence and limits · Project source

Recorded case source: db2594d6ff15d75151785c388ed35c473533d3b9